Where does the line lose time?
Stops with their reasons, grouped into a Pareto, show whether the loss is a filler jam, a missing material or a changeover.
Process manufacturing · line view
Lines, PLCs and batches. MDCplus reads PLC signals to show line state, stops, throughput and batch times, so you see where a line loses time. It measures the line. It does not control the process.
Simulation, not customer data. Blocked and starved states need the PLC to provide the signals.
Machine monitoring for process manufacturing means reading the signals a line's PLCs already have, such as running, fault, product count, reject count and batch start and stop, and turning them into line state, downtime, throughput, OEE and batch times. It sits next to SCADA, MES and laboratory systems, and it does not replace them: it answers where the line loses time, not how to run the process.
From signal to number
Click a signal to see what it turns into.
Where it sits
MDCplus is not a replacement for any of them. It answers one question: where does the line lose time.
Straight answers
Stops with their reasons, grouped into a Pareto, show whether the loss is a filler jam, a missing material or a changeover.
Blocked and starved states of neighbouring stations show which station sets the pace of the line.
Time between the last good unit of one product and the first of the next, for every changeover.
Batch start and stop from the PLC give batch times to compare between shifts and lines.
PLCs first
A line is connected through its PLC. MDCplus supports more than 100 open protocols, and one PLC or HMI counts as one data collection point for licensing. It is installed on premise and can work fully inside a closed network without internet access, and it reads the line without writing to it.
Open the machine connectivity checker to see the connection route for your equipment.
Tell us the PLC types on your lines and the signals they provide. We will answer what can be shown and what a sensible first line looks like.
No. A SCADA system supervises and controls the process. MDCplus reads data from PLCs and machines, read-only, to report line state, stops, throughput and OEE. It does not control the process.
Yes. A line is connected through its PLC, and one PLC or HMI is counted as one data collection point for licensing. MDCplus supports more than 100 open protocols.
Line state, stops with their reasons, throughput from product counters, rejects, changeover time between products and batch times, depending on the signals the PLC provides.
No. MDCplus does not manage recipes, batch records or laboratory data. It can send machine data to a MES or ERP through the API.
Yes, when the PLC provides the running state and product and reject counters. The ideal rate for the product is then used to calculate performance.
Yes. MDCplus is installed on premise and can work fully inside a closed network without internet access.
The first machine is connected within 1 to 2 hours. MDCplus is a perpetual license per data collection point, where one PLC or HMI is one license, and the price includes implementation and the server license.
Technical library
Last updated: . Prepared by the MDCplus team.